Efficient Cooling Technology
The exclusive use of high-quality compressors and of the plated heat exchanger, ensures high performance and low energy consumption. The set of technologies used allows you to decrease noise levels and achieve the highest COP (Coefficient of Performance) contributing to significant energy savings.
Digital Thermostat
Intuitive setting of functions and accurate temperature detection, resolution 0,1°C/1°F. The setting range is 3°-20°C (37,4°F – 68°F) and there is a closed loop temperature control system with high accuracy and extremely tight differential 0.5°C/0.5°F. Displayed temperature is in °C or °F and there are security alarms.
Efficient Design
The chiller, with its innovative design, is characterized by a solid structure designed to guarantee a perfect protection against rust. The functionality of the shape and the compact size are also suitable for confined spaces.
Unique Features
CP5 is specially designed to work at low temperatures. It is the ideal chiller to keep water for ice baths at the desired temperature.
WARNING: The CP5 chiller is not suitable for the use with seawater or water salts have been added to.
If chlorine is used, the concentration of free chlorine in the water must be less than 1 ppm for less than 5 hours.
Use a pump that, once installed in the system, generates a flow rate greater than 750 l/h (pump’s flow: at least 8000 l/h – 4,5 m height, if the height of the water above the pump is approximately 1 meter).
If chlorine is used, the concentration of free chlorine in the water must be less than 1 ppm for less than 5 hours.
Use a pump that, once installed in the system, generates a flow rate greater than 750 l/h (pump’s flow: at least 8000 l/h – 4,5 m height, if the height of the water above the pump is approximately 1 meter).
Power supply | Water temp. | Liters* | US Gallons | COP** |
---|---|---|---|---|
230V | 5°C – 41°F | 300 (not isolated tank) | 79,2 | 1.43 |
230V | 5°C – 41°F | 450 (isolated tank) | 118,8 | 1.43 |
230V | 5°C – 41°F | 800 (highly isolated tank) | 211,3 | 1.43 |
* The values reported in the table refer to the following conditions: room temp. 30°C, water flow 900 l/h.
** Coefficient of performance.
** Coefficient of performance.
Voltage | Frequency | Gas | Weight | Room temperature | Power consumption |
---|---|---|---|---|---|
230V | 50 Hz | R290 | 25 kg – 54,9 lb | 16°C – 32°C / 60°F – 90°F | 420W* |
230V | 50 Hz | R290 | 25 kg – 54,9 lb | 16°C – 32°C / 60°F – 90°F | 440W** |
*The values reported in the table refer to the following condition: room temperature 32°C , water temperature 5°C, water flow 900 l/h
** The values reported in the table refer to the following condition: room temperature 32°C, water temperature 25°C (77°F), water flow 900 l/h
** The values reported in the table refer to the following condition: room temperature 32°C, water temperature 25°C (77°F), water flow 900 l/h